애스크로AIPublic Preview
← 학술논문 검색
학술논문Yonsei Medical Journal2008.04 발행KCI 피인용 4

Outcome Following Surgical Closure of Patent Ductus Arteriosus in Very Low Birth Weight Infants in Neonatal Intensive Care Unit

Outcome Following Surgical Closure of Patent Ductus Arteriosus in Very Low Birth Weight Infants in Neonatal Intensive Care Unit

이가연(성균관대학교); 손영배(성균관대학교); 김묘징(성균관대학교); 전가원(성균관대학교); 심재원(성균관대학교); 장윤실(성균관대학교); 허준(성균관대학교); 강이석(성균관대학교); 양지혁(성균관대학교); 전태국(성균관대학교); 박표원(성균관대학교); 박원순(성균관대학교); 이흥재(성균관대학교)

49권 2호, 265~271쪽

초록

Purpose: The aims of this study were to determine the factors affecting the outcome of patent ductus arteriosus ligation in very low birth weight infants (VLBWI) and demonstrate the safety of PDA ligation in VLBWI performed in the neonatal intensive care unit (NICU). Materials and Methods: From October 1994 to July 2006, medical records of 94 VLBWI weighing <1,500g who underwent PDA ligation in the NICU of Samsung Medical Center were reviewed retrospectively. Factors affecting the final outcome of PDA ligation were evaluated by dividing the infants into 3 groups according to mortality and major morbidities as follows: mortality group (Mo), major morbidity group (Mb), and no major morbidity group (NM). Results: In the Mo group, birth weight was significantly lower and the preoperative mean FiO2 and mean dopamine dose were significantly higher than those in the other 2 groups. There was no significant difference in gestational age, incidence of RDS, number of courses of indomethacin, surgery-related factors, including weight and age at surgery, perioperative vital signs, and complications after surgery between the 3 groups. During surgery in the NICU, there were no significant hemodynamic instability or serious acute complications. Conclusion: The factors affecting the outcome of surgery in VLBWI are not the factors related to surgery but the preoperative conditions related to the underlying prematurity. PDA ligation of VLBWI performed in the NICU is safe without serious complications.

Abstract

Purpose: The aims of this study were to determine the factors affecting the outcome of patent ductus arteriosus ligation in very low birth weight infants (VLBWI) and demonstrate the safety of PDA ligation in VLBWI performed in the neonatal intensive care unit (NICU). Materials and Methods: From October 1994 to July 2006, medical records of 94 VLBWI weighing <1,500g who underwent PDA ligation in the NICU of Samsung Medical Center were reviewed retrospectively. Factors affecting the final outcome of PDA ligation were evaluated by dividing the infants into 3 groups according to mortality and major morbidities as follows: mortality group (Mo), major morbidity group (Mb), and no major morbidity group (NM). Results: In the Mo group, birth weight was significantly lower and the preoperative mean FiO2 and mean dopamine dose were significantly higher than those in the other 2 groups. There was no significant difference in gestational age, incidence of RDS, number of courses of indomethacin, surgery-related factors, including weight and age at surgery, perioperative vital signs, and complications after surgery between the 3 groups. During surgery in the NICU, there were no significant hemodynamic instability or serious acute complications. Conclusion: The factors affecting the outcome of surgery in VLBWI are not the factors related to surgery but the preoperative conditions related to the underlying prematurity. PDA ligation of VLBWI performed in the NICU is safe without serious complications.

발행기관:
연세대학교의과대학
분류:
의학일반

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
Outcome Following Surgical Closure of Patent Ductus Arteriosus in Very Low Birth Weight Infants in Neonatal Intensive Care Unit | Yonsei Medical Journal 2008 | AskLaw | 애스크로 AI