Multivariate monitoring for time-derivative non-Gaussian batch process

Multivariate monitoring for time-derivative non-Gaussian batch process

Chang Kyoo Yoo(Kyung Hee University); Min Han Kim(Kyung Hee University)

25권 5호, 947~954쪽

초록

This research is an application of process monitoring on a pilot-scale sequencing batch reactor (SBR) using a batchwise multiway independent component analysis method (MICA) for denoising effect, which can extract meaningful hidden information from non-Gaussian data. Three-way batch data of SBR are unfolded batch wise, and then a multivariate monitoring method is used to capture the non-Gaussian and nonlinear characteristics of normal batches. It is successfully applied to an 80 L SBR for biological wastewater treatment, which is characterized by a variety of error sources with non-Gaussian characteristics. In the monitoring result, multiway principal component analysis (MPCA) can detect the abnormal batches with a false alarm rate of 47.5%, whereas MICA charts show less false alarm rate of 4.5%. The results of this pilot-scale SBR monitoring system using simple on-line measurements clearly demonstrated that the MICA monitoring technique showed lower false alarm rate and physically meaningful robust monitoring results.

Abstract

This research is an application of process monitoring on a pilot-scale sequencing batch reactor (SBR) using a batchwise multiway independent component analysis method (MICA) for denoising effect, which can extract meaningful hidden information from non-Gaussian data. Three-way batch data of SBR are unfolded batch wise, and then a multivariate monitoring method is used to capture the non-Gaussian and nonlinear characteristics of normal batches. It is successfully applied to an 80 L SBR for biological wastewater treatment, which is characterized by a variety of error sources with non-Gaussian characteristics. In the monitoring result, multiway principal component analysis (MPCA) can detect the abnormal batches with a false alarm rate of 47.5%, whereas MICA charts show less false alarm rate of 4.5%. The results of this pilot-scale SBR monitoring system using simple on-line measurements clearly demonstrated that the MICA monitoring technique showed lower false alarm rate and physically meaningful robust monitoring results.

발행기관:
한국화학공학회
분류:
화학공학

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
Multivariate monitoring for time-derivative non-Gaussian batch process | Korean Journal of Chemical Engineering 2008 | AskLaw | 애스크로 AI