액체 침투 특성과 표면 거동 분석을 이용한 사이즈도 자동측정법
Automatic Test Method of Sizing Degree by Analysis of Liquid Penetration and its Surface Behavior
이지영(경상대학교); 김철환(경상대학교); 김경철(경상대학교); M.I. Sheikh(경상대학교); 박현진(경상대학교); 김성호(경상대학교); 심성웅(경상대학교); 조후승(경상대학교)
44권 2호, 18~28쪽
초록
This study was to develop a novel automatic system for measuring Stöckigt sizing degree and contact angle at a time. The conventional methods to measure sizing degree had serious problems in obtaining significant differences according to different dosages of a sizing agent, and moreover they disclosed unique limitation due to liquid types used and tester’s subjectivity. However, the newly developed system could get reproducible results through total automation of all procedures including liquid dropping,image acquisition and measurement of both Stöckigt sizing degree and contact angle. For the Stöckigt sizing test, the automatic system could measure sizing degree with more definite differences according to different dosage of AKD, compared to the conventional method. For the contact angle test, the automatic system showed a similar trend to the conventional method but had smaller contact angles due to distortion of an image focus by a sheet curl than the conventional testing machine. The problem from the image out of focus due to specimen curl will be overcome with adopting a new specimen holder for the future system.
Abstract
This study was to develop a novel automatic system for measuring Stöckigt sizing degree and contact angle at a time. The conventional methods to measure sizing degree had serious problems in obtaining significant differences according to different dosages of a sizing agent, and moreover they disclosed unique limitation due to liquid types used and tester’s subjectivity. However, the newly developed system could get reproducible results through total automation of all procedures including liquid dropping,image acquisition and measurement of both Stöckigt sizing degree and contact angle. For the Stöckigt sizing test, the automatic system could measure sizing degree with more definite differences according to different dosage of AKD, compared to the conventional method. For the contact angle test, the automatic system showed a similar trend to the conventional method but had smaller contact angles due to distortion of an image focus by a sheet curl than the conventional testing machine. The problem from the image out of focus due to specimen curl will be overcome with adopting a new specimen holder for the future system.
- 발행기관:
- 한국펄프·종이공학회
- DOI:
- http://dx.doi.org/
- 분류:
- 임학