An Incidentally Detected Breast Cancer on Tc-99m MIBI Cardiac Scintigraphy

An Incidentally Detected Breast Cancer on Tc-99m MIBI Cardiac Scintigraphy

Duray Seker(Diskapi Yildirim Beyazit Teaching and Research Hospital); Gaye Seker(Diskapi Yildirim Beyazit Teaching and Research Hospital); Emine Ozturk(Diskapi Yildirim Beyazit Teaching and Research Hospital); Bahattin Bayar(Diskapi Yildirim Beyazit Teaching and Research Hospital); Hakan Kulacoglu(Diskapi Yildirim Beyazit Teaching and Research Hospital)

15권 2호, 252~254쪽

초록

Tc-99m methoxyisobutylisonitrile (MIBI) scintigraphy is generally used as a second-line diagnostic tool for obscured breast lesions. When the entire field of view is examined carefully, it is often possible to detect additional lesions unrelated to the initial intent and purpose of the examination. Herein we present a case of breast cancer incidentally detected by cardiac Tc-99m MIBI scintigraphy. An area of uptake was detected in the breast during a cardiac imaging test. Further evaluation of this lesion revealed a histopathological diagnosis of invasive ductal carcinoma of the breast. Sensitivity of this scintigraphic technique is not enough sufficient to use this test as a screening test for breast cancer, but it may provide supplemental information. Since it is not uncommon to find incidental lesions during imaging studies, examination of the image field may help clinicians find otherwise unrecognized or undiagnosed pathologies.

Abstract

Tc-99m methoxyisobutylisonitrile (MIBI) scintigraphy is generally used as a second-line diagnostic tool for obscured breast lesions. When the entire field of view is examined carefully, it is often possible to detect additional lesions unrelated to the initial intent and purpose of the examination. Herein we present a case of breast cancer incidentally detected by cardiac Tc-99m MIBI scintigraphy. An area of uptake was detected in the breast during a cardiac imaging test. Further evaluation of this lesion revealed a histopathological diagnosis of invasive ductal carcinoma of the breast. Sensitivity of this scintigraphic technique is not enough sufficient to use this test as a screening test for breast cancer, but it may provide supplemental information. Since it is not uncommon to find incidental lesions during imaging studies, examination of the image field may help clinicians find otherwise unrecognized or undiagnosed pathologies.

발행기관:
한국유방암학회
DOI:
http://dx.doi.org/10.4048/jbc.2012.15.2.252
분류:
종양외과/외과종양

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
An Incidentally Detected Breast Cancer on Tc-99m MIBI Cardiac Scintigraphy | Journal of Breast Cancer 2012 | AskLaw | 애스크로 AI