전자처리 스페클 패턴 간섭법(ESPI)을 이용한 3-유닛 고정성 국소의치의 변형특성 분석

Deformation Characteristics Analysis of 3-Unit Fixed Partial Dentures by Using Electronic Speckle Pattern Interferometry

강후원(동아인재대학교); 이철민(동아인재대학교 안경광학과); 양승필(동아인재대학교); 김희진(부산카톨릭대학교 치기공학과)

35권 1호, 49~56쪽

초록

Purpose: The deformation characteristics induced by non-destructive stresses using piezoelectric transducer(PZT)were analyzed for 3-unit fixed partial dentures manufactured PFM, Everest(CAD/CAM) and Zirkonzahn(copy milling, MAD/MAM) by electron speckle pattern interferometery(ESPI). Methods: The ESPI analysis after loading the restoration with PZT by applying electric voltage of 900mV at the points of 10 above the base of the prostheses. Results: PFM and All-Ceramic Everest prostheses showed about 0.1 while that of All- Ceramic Zirkonzahn prostheses showed 0.085 , demonstrating that Zirkonzahn displaced less. For PFM and All-Ceramic Zirkonzahn prostheses, the displacements were large at just below the loading point, while generalize displacement was shown over the loading point and weak connector areas for All-Ceramic Everest prostheses. Conclusion: We could find that the deformation characteristics induced by non-destructive stresses using PZT analyzed by ESPI were similar to the fracture strengths evaluated using universal testing machine.

Abstract

Purpose: The deformation characteristics induced by non-destructive stresses using piezoelectric transducer(PZT)were analyzed for 3-unit fixed partial dentures manufactured PFM, Everest(CAD/CAM) and Zirkonzahn(copy milling, MAD/MAM) by electron speckle pattern interferometery(ESPI). Methods: The ESPI analysis after loading the restoration with PZT by applying electric voltage of 900mV at the points of 10 above the base of the prostheses. Results: PFM and All-Ceramic Everest prostheses showed about 0.1 while that of All- Ceramic Zirkonzahn prostheses showed 0.085 , demonstrating that Zirkonzahn displaced less. For PFM and All-Ceramic Zirkonzahn prostheses, the displacements were large at just below the loading point, while generalize displacement was shown over the loading point and weak connector areas for All-Ceramic Everest prostheses. Conclusion: We could find that the deformation characteristics induced by non-destructive stresses using PZT analyzed by ESPI were similar to the fracture strengths evaluated using universal testing machine.

발행기관:
대한치과기공학회
분류:
기타치의학

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
전자처리 스페클 패턴 간섭법(ESPI)을 이용한 3-유닛 고정성 국소의치의 변형특성 분석 | 대한치과기공학회지 2013 | AskLaw | 애스크로 AI