광자극발광법과 열발광법 분석을 통한 전자선과 감마선 조사식품의 비교 연구
Comparison of Irradiated Food with Electron Beam and Gamma-ray by PSL and TL Methods
김규헌(식품의약품안전처 식품의약품안전평가원 식품위해평가부 신종유해물질팀); 곽지영(식품의약품안전처 식품의약품안전평가원 식품위해평가부 신종유해물질팀); 윤진호(식품의약품안전처 식품의약품안전평가원 식품위해평가부 신종유해물질팀); 박영은(식품의약품안전처 식품의약품안전평가원 식품위해평가부 신종유해물질팀); 이재황(식품의약품안전처 식품의약품안전평가원 식품위해평가부 신종유해물질팀); 박용춘(식품의약품안전처 신소재식품과); 조태용(부산지방식품의약품안전청 유해물질분석팀); 이화정(식품의약품안전평강원 첨가물포장과); 이상재(식품의약품안전처 식품의약품안전평가원 식품위해평가부 신종유해물질팀); 한상배(식품의약품안전청)
28권 3호, 258~266쪽
초록
This study was conducted to determine the PSL and TL properties of foods irradiated with electron beam and gamma-ray. 5 kinds of food including cereal, pulse, fish powder, dried vegetable and tea were irradiated at 0 to 10 kGy by electron beam accelerator or 60Co gamma-ray irradiator. The PSL analysis showed negative results for most of the non-irradiated samples. Non-irradiated shrimp powder showed intermediate result. Irradiated samples gave negative or intermediate or positive value which presented the limitation of PSL technique. In TL analysis, there were TL glow curves at around 300oC with low intensity on non-irradiated samples. Maximum peak in the range of 150-250oC was appeared on irradiated samples. TL ratio obtained by re-irradiation with 1 kGy was less than 0.1 on non-irradiated samples and higher than 0.1 on irradiated samples. Therefore, in PSL measurement, electron-beam irradiated samples could obtain more clear results. TL analysis showed obvious difference between non-irradiated and irradiated samples. But the identification was impossible for the sample of rice and lemon tea. Because of it's low contents of mineral.
Abstract
This study was conducted to determine the PSL and TL properties of foods irradiated with electron beam and gamma-ray. 5 kinds of food including cereal, pulse, fish powder, dried vegetable and tea were irradiated at 0 to 10 kGy by electron beam accelerator or 60Co gamma-ray irradiator. The PSL analysis showed negative results for most of the non-irradiated samples. Non-irradiated shrimp powder showed intermediate result. Irradiated samples gave negative or intermediate or positive value which presented the limitation of PSL technique. In TL analysis, there were TL glow curves at around 300oC with low intensity on non-irradiated samples. Maximum peak in the range of 150-250oC was appeared on irradiated samples. TL ratio obtained by re-irradiation with 1 kGy was less than 0.1 on non-irradiated samples and higher than 0.1 on irradiated samples. Therefore, in PSL measurement, electron-beam irradiated samples could obtain more clear results. TL analysis showed obvious difference between non-irradiated and irradiated samples. But the identification was impossible for the sample of rice and lemon tea. Because of it's low contents of mineral.
- 발행기관:
- 한국식품위생안전성학회
- 분류:
- 식품위생/안전