Enhancement Effect of Cell Adhesion on Titanium Surface Using Phosphonated Low-Molecular-Weight Chitosan Derivative
Enhancement Effect of Cell Adhesion on Titanium Surface Using Phosphonated Low-Molecular-Weight Chitosan Derivative
김은혜(중앙대학교); 박신혜(RIKEN Advanced Science Institute); 지소윤(중앙대학교); 우희동(중앙대학교); 허윤(중앙대학교); Yoshihiro Ito(RIKEN Advanced Science Institute); 한동근(한국과학기술연구원); 나재운(순천대학교); 손태일(중앙대학교)
24권 2호, 99~103쪽
초록
For improving cell adhesion on titanium surface, phosphonated low-molecular-weight chitosan (P-LMC) was prepared by introducing a phosphonate group of 4-phosphonobutyric acid to low-molecular-weight chitosan (3,000<MW<10,000). The phosphonate group of P-LMC was identified by 31P NMR. At about 30 ppm from external standard, there was a specific peak derived from phosphonate group. X-Ray Photoelectron Spectroscopy (XPS) and water contact angle were carried out for characterization of titanium surface treated with P-LMC. From these results, P-LMC coated on titanium surface was remained on that in spite of washing and P-LMC made titanium surface more hydrophilic. The biocompatibility of P-LMC was demonstrated through a cytotoxicity test using the C2C12 cell line because P-LMC should have no cytotoxicity for applying to dental implant materials. As a result, P-LMC was biocompatible to use as coating material of titanium. Improvement of cell adhesion on titanium surface treated with P-LMC was observed by microscopy, and the number of attached cells was counted using a hemocytometer. Titanium surface coated with P-LMC showed improved cell adhesion for 12 h. These results demonstrate that P-LMC is biocompatible and titanium surface treated with P-LMC has positive effects on cell adhesion. Therefore, P-LMC is a useful material that can be applied for titanium coating to enhance cell adhesion and osseointegration.
Abstract
For improving cell adhesion on titanium surface, phosphonated low-molecular-weight chitosan (P-LMC) was prepared by introducing a phosphonate group of 4-phosphonobutyric acid to low-molecular-weight chitosan (3,000<MW<10,000). The phosphonate group of P-LMC was identified by 31P NMR. At about 30 ppm from external standard, there was a specific peak derived from phosphonate group. X-Ray Photoelectron Spectroscopy (XPS) and water contact angle were carried out for characterization of titanium surface treated with P-LMC. From these results, P-LMC coated on titanium surface was remained on that in spite of washing and P-LMC made titanium surface more hydrophilic. The biocompatibility of P-LMC was demonstrated through a cytotoxicity test using the C2C12 cell line because P-LMC should have no cytotoxicity for applying to dental implant materials. As a result, P-LMC was biocompatible to use as coating material of titanium. Improvement of cell adhesion on titanium surface treated with P-LMC was observed by microscopy, and the number of attached cells was counted using a hemocytometer. Titanium surface coated with P-LMC showed improved cell adhesion for 12 h. These results demonstrate that P-LMC is biocompatible and titanium surface treated with P-LMC has positive effects on cell adhesion. Therefore, P-LMC is a useful material that can be applied for titanium coating to enhance cell adhesion and osseointegration.
- 발행기관:
- 한국고분자학회
- 분류:
- 고분자공학