애스크로AIPublic Preview
← 학술논문 검색
학술논문Clinical and Experimental Pediatrics2016.04 발행KCI 피인용 5

Correlation of B-type natriuretic peptide levels and echocardiographic parameters in preterm infants with patent ductus arteriosus

Correlation of B-type natriuretic peptide levels and echocardiographic parameters in preterm infants with patent ductus arteriosus

Hyun Ah Jeong(Korea University); Jeong Hee Shin(Korea University); Eun Ji Kim(Korea University); Eunhee Lee(Korea University); Byung-Min Choi(Korea University); Chang Sung Son(Korea University); Joo Won Lee(Korea University)

57권 4호, 183~189쪽

초록

Purpose: This study aimed to evaluate the correlation, according to postnatal age, between plasma B-type natriuretic peptide (BNP) levels and echocardiographic parameters for the assessment of patent ductus arteriosus (PDA) in preterm infants with respiratory distress. Methods: We enrolled 42 preterm infants with respiratory distress who underwent serial echocardiographic evaluation with simultaneous plasma BNP measurements until ductal closure. The correlations between BNP levels and the following 4 representative echocardiographic parameters were studied: diameter of the ductus arteriosus (DA), ratio of the left atrial diameter to the aortic diameter (LA/Ao), ratio of the PDA diameter to the infant’s left pulmonary artery diameter (PDA/LPA), and the antegrade diastolic flow of LPA (DFLPA). Results: BNP levels were significantly correlated to the magnitude of the ductal shunt, comprising the DA diameter, PDA/LPA ratio, LA/Ao ratio, and antegrade DFLPA for the overall study period. The earliest significant correlation, starting from postnatal day 2, was observed between the LA/Ao ratio and BNP levels. The PDA/LPA ratio and the antegrade DFLPA showed significant correlations with BNP levels postnatal day 3 onward, and with the DA diameter, postnatal day 5 onward. Conclusion: BNP levels and echocardiographic parameters showed a positive correlation, but the significance of the correlations differed according to the postnatal age, especially during the first few days of life.

Abstract

Purpose: This study aimed to evaluate the correlation, according to postnatal age, between plasma B-type natriuretic peptide (BNP) levels and echocardiographic parameters for the assessment of patent ductus arteriosus (PDA) in preterm infants with respiratory distress. Methods: We enrolled 42 preterm infants with respiratory distress who underwent serial echocardiographic evaluation with simultaneous plasma BNP measurements until ductal closure. The correlations between BNP levels and the following 4 representative echocardiographic parameters were studied: diameter of the ductus arteriosus (DA), ratio of the left atrial diameter to the aortic diameter (LA/Ao), ratio of the PDA diameter to the infant’s left pulmonary artery diameter (PDA/LPA), and the antegrade diastolic flow of LPA (DFLPA). Results: BNP levels were significantly correlated to the magnitude of the ductal shunt, comprising the DA diameter, PDA/LPA ratio, LA/Ao ratio, and antegrade DFLPA for the overall study period. The earliest significant correlation, starting from postnatal day 2, was observed between the LA/Ao ratio and BNP levels. The PDA/LPA ratio and the antegrade DFLPA showed significant correlations with BNP levels postnatal day 3 onward, and with the DA diameter, postnatal day 5 onward. Conclusion: BNP levels and echocardiographic parameters showed a positive correlation, but the significance of the correlations differed according to the postnatal age, especially during the first few days of life.

발행기관:
대한소아청소년과학회
분류:
소아과학

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
Correlation of B-type natriuretic peptide levels and echocardiographic parameters in preterm infants with patent ductus arteriosus | Clinical and Experimental Pediatrics 2016 | AskLaw | 애스크로 AI