반도체용 과산화수소 중 음이온 분석을 위한 헤드스페이스 고상마이크로 추출법을 활용한 기체크로마토그래피-질량분석법 개발
Determinations of Trace Level Anions in Hydrogen Peroxide for Semiconductor by Headspace Solid Phase Microextraction and Gas Chromatography-Mass Spectrometry
신호상(공주대학교)
19권 3호, 192~198쪽
초록
An ultrasensitive method to detect trace anions (fluoride, nitrite and nitrate) in hydrogen peroxide (H2O2) for semiconductor by headspace solid phase microextraction (HS-SPME) gas chromatography-mass spectrometry (GC-MS) was described. Fluoride, nitrite and nitrate in hydrogen peroxide reacted with pentafluorobenzyl bromide (PFB-Br) in a headspace vial and the formed PFB derivatives were vaporized and adsorbed onto a fiber. The optimal HS-SPME conditions were achieved with a 50/30 μm divinylbenzene-carboxen- polydimethylsiloxan (DVB-CAR-PDMS) fiber, 50 μL of PFB-Br (99%), 100 μL of 10% tetraoctylammonium bromide (10%) as a phase transfer catalyst, an extraction/derivatization temperature of 90oC, a heating time of 50 min, and a pH of 6.0. Under the established conditions, the method detection limits of fluoride, nitrite and nitrate were 2.8-4.0 μg/L in 30% H2O2 solutions (w/w) and the relative standard deviations were less than 4% at concentrations of 25 and 50 μg/L. The concentrations of anions in five concentrated H2O2 had detectable levels of 8.7 to 28.4 μg/L. The method was sensitive, reproducible and simple enough to permit the reliable routine analysis of anions in hydrogen peroxide for semiconductor
Abstract
An ultrasensitive method to detect trace anions (fluoride, nitrite and nitrate) in hydrogen peroxide (H2O2) for semiconductor by headspace solid phase microextraction (HS-SPME) gas chromatography-mass spectrometry (GC-MS) was described. Fluoride, nitrite and nitrate in hydrogen peroxide reacted with pentafluorobenzyl bromide (PFB-Br) in a headspace vial and the formed PFB derivatives were vaporized and adsorbed onto a fiber. The optimal HS-SPME conditions were achieved with a 50/30 μm divinylbenzene-carboxen- polydimethylsiloxan (DVB-CAR-PDMS) fiber, 50 μL of PFB-Br (99%), 100 μL of 10% tetraoctylammonium bromide (10%) as a phase transfer catalyst, an extraction/derivatization temperature of 90oC, a heating time of 50 min, and a pH of 6.0. Under the established conditions, the method detection limits of fluoride, nitrite and nitrate were 2.8-4.0 μg/L in 30% H2O2 solutions (w/w) and the relative standard deviations were less than 4% at concentrations of 25 and 50 μg/L. The concentrations of anions in five concentrated H2O2 had detectable levels of 8.7 to 28.4 μg/L. The method was sensitive, reproducible and simple enough to permit the reliable routine analysis of anions in hydrogen peroxide for semiconductor
- 발행기관:
- 한국환경분석학회
- 분류:
- 환경분석화학