Prolonged reflex bradycardia after occlusion of patent ductus arteriosus with an Amplatz canine duct occluder in a dog
Prolonged reflex bradycardia after occlusion of patent ductus arteriosus with an Amplatz canine duct occluder in a dog
노웅빈(건국대학교); 강민희(건국대학교); 이창민(건국대학교); 김승곤(건국대학교 수의과학연구소); 박희명(건국대학교)
57권 1호, 51~54쪽
초록
A 9-month-old intact male Maltese dog (1.52 kg) was diagnosed with a patent ductus arteriosus (PDA). Transcatheter occlusion of the PDA was performed by using the Amplatz canine duct occluder (ACDO). After occlusion, reflex bradycardia occurred and lasted for at least 15 h with normal systolic arterial pressure and slightly increased diastolic arterial pressure. The bradycardia slowly resolved, and the heart rate was normal in re-examinations after 7 and 30 days. This is the first case of reflex bradycardia after ACDO implantation, in which the bradycardia continued for a long time, even after recovery from anesthesia.
Abstract
A 9-month-old intact male Maltese dog (1.52 kg) was diagnosed with a patent ductus arteriosus (PDA). Transcatheter occlusion of the PDA was performed by using the Amplatz canine duct occluder (ACDO). After occlusion, reflex bradycardia occurred and lasted for at least 15 h with normal systolic arterial pressure and slightly increased diastolic arterial pressure. The bradycardia slowly resolved, and the heart rate was normal in re-examinations after 7 and 30 days. This is the first case of reflex bradycardia after ACDO implantation, in which the bradycardia continued for a long time, even after recovery from anesthesia.