다중이용시설 등의 실내공기질 관리법에 따른 실태 분석 및 평가

Reality analysis and evaluation according to indoor air quality management law of multi-use facilities

최지희(순천향대학교); 박희진(순천향대학교); 오유진(순천향대학교); 안지희(순천향대학교); 박주선(순천향대학교); 김광래(서울시보건환경연구원); 신진호(서울특별시 보건환경연구원); 어수미(서울특별시 보건환경연구원); 정권(서울특별시 보건환경연구원); 이종화(순천향대학교); 장봉기(순천향대학교); 손부순(순천향대학교)

16권 2호, 175~181쪽

초록

In this study, the distribution of each facility group, the pollution level of local municipalities and the status ofself-measurement were investigated and analyzed using data provided by the Ministry of Environment. It wasfound that most of the workplaces to be managed are facilities of sensitive class, indoor parking lots and largescalestores. The results of the survey on the total pollution level by facility group showed that the rate ofcontamination was the highest in the facilities where there are many sensitive users, including the subway stationand the underground shopping malls. Through self-measurement, in the case of fine particle matter, it was foundthat it was present in amounts of 51.71 μg/m3, 50.72 μg/m3, 44.47 μg/m3 and 54.44 μg/m3 in medical institutions,day care centers, elderly care facilities and postnatal care centers, respectively. Also, there were facilities exceedingthe standard in the medical institutions. However, most of the pollutants in the facilities surveyed by the municipalityare higher than the self-measured concentrations, so it is necessary to examine the cause of such pollution.

Abstract

In this study, the distribution of each facility group, the pollution level of local municipalities and the status ofself-measurement were investigated and analyzed using data provided by the Ministry of Environment. It wasfound that most of the workplaces to be managed are facilities of sensitive class, indoor parking lots and largescalestores. The results of the survey on the total pollution level by facility group showed that the rate ofcontamination was the highest in the facilities where there are many sensitive users, including the subway stationand the underground shopping malls. Through self-measurement, in the case of fine particle matter, it was foundthat it was present in amounts of 51.71 μg/m3, 50.72 μg/m3, 44.47 μg/m3 and 54.44 μg/m3 in medical institutions,day care centers, elderly care facilities and postnatal care centers, respectively. Also, there were facilities exceedingthe standard in the medical institutions. However, most of the pollutants in the facilities surveyed by the municipalityare higher than the self-measured concentrations, so it is necessary to examine the cause of such pollution.

발행기관:
한국냄새환경학회
DOI:
http://dx.doi.org/10.15250/joie.2017.16.2.175
분류:
기타환경공학

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
다중이용시설 등의 실내공기질 관리법에 따른 실태 분석 및 평가 | 실내환경 및 냄새 학회지 2017 | AskLaw | 애스크로 AI