애스크로AIPublic Preview
← 학술논문 검색
학술논문Journal of Yeungnam Medical Science1999.06 발행

관상동맥질환 진단에서 Thallium-201과 Technetium-99m MIBI를 이용한 Dual-Isotope SPECT 영상

Dual-Isotope SPECT Imaging with Thallium-201 and Technetium-99m MIBI in Detecting Coronary Artery Disease

이규광(영남대학교 의과대학 핵의학교실); 조인호(영남대학교); 이형우(영남대학교); 박종선(영남대학교); 원규장(영남대학교); 신동구(영남대학교); 김영조(영남대학교); 심봉섭(영남대학교)

16권 1호, 101~107쪽

초록

We evaluated the results of sequential SPECT dual-isotope imaging with Tl-201 and Tc-99m MIBI in 24 patients, all of whom also had coronary angiography within the past one month. Coronary angiography showed that 12 patients had no CAD, 4 patients had one-vessel CAD, 7 patients had two-vessel CAD and 1 patient had three-vessel CAD. Serial studies of resting Tl-201 and dipyridamole stress Tc-99m MIBI were completed within 2 hours. When more then 50% of coronary artery narrowing was considered significant. The overall sensitivity and specification of CAD detection were 91.7%. The sensitivity of CAD detection in patients with one-vessel and multi-vessel diseases was 75% and 100%, respectively. Therefore, sequential dual-isotope SPECT demonstrated high sensitivity and specificity of CAD detection. In conclusion, sequential dual-isotope imaging is feasible and can be completed in a short time and may therefore enhance laboratory throughput and patient convenience.

Abstract

We evaluated the results of sequential SPECT dual-isotope imaging with Tl-201 and Tc-99m MIBI in 24 patients, all of whom also had coronary angiography within the past one month. Coronary angiography showed that 12 patients had no CAD, 4 patients had one-vessel CAD, 7 patients had two-vessel CAD and 1 patient had three-vessel CAD. Serial studies of resting Tl-201 and dipyridamole stress Tc-99m MIBI were completed within 2 hours. When more then 50% of coronary artery narrowing was considered significant. The overall sensitivity and specification of CAD detection were 91.7%. The sensitivity of CAD detection in patients with one-vessel and multi-vessel diseases was 75% and 100%, respectively. Therefore, sequential dual-isotope SPECT demonstrated high sensitivity and specificity of CAD detection. In conclusion, sequential dual-isotope imaging is feasible and can be completed in a short time and may therefore enhance laboratory throughput and patient convenience.

발행기관:
영남대학교 의과대학
분류:
의학일반

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
관상동맥질환 진단에서 Thallium-201과 Technetium-99m MIBI를 이용한 Dual-Isotope SPECT 영상 | Journal of Yeungnam Medical Science 1999 | AskLaw | 애스크로 AI