축열교정법에 의한 공동주택 외벽체 동절기 현장 열저항과 열관류율 측정 및 분석
Measurement and Analysis of In-situ Thermal Resistance and Thermal Transmittance of Apartment House Opaque Exterior Wall during Winter Season by Application of Thermal Storage Effect
고명진(순천제일대학교 소방방재과); 최두성(청운대학교)
24권 6호, 802~809쪽
초록
This study evaluates the possibility of shortening measurement time to obtain the accurate in situ thermaltransmittance (U-value) and thermal resistance (R-value) by the average method considering the thermal storage effect(AMSE) compared to the progressive average method (PAM). The measurement campaign was conducted on the opaqueexternal wall of an apartment house located in Seoul for two weeks in the winter and was performed in compliancewith the ISO 9869-1 standard. As a results of the measurement, U-value and R-value analyzed by PAM did not convergeduring the two weeks period, even though the experimental conditions specified in ISO 9869-1 were met. The analyticalresults by AMSE show that as the correction period to apply the storage effect becomes longer, the fluctuation of Uvalueand R-value greatly decrease and two values tend to converge to the respective asymptotical values. Therefore,although extensive research is needed for more cases, it is considered that AMSE can shorten the measurement periodto determine the U-value and R-value to a reasonable level of accuracy.
Abstract
This study evaluates the possibility of shortening measurement time to obtain the accurate in situ thermaltransmittance (U-value) and thermal resistance (R-value) by the average method considering the thermal storage effect(AMSE) compared to the progressive average method (PAM). The measurement campaign was conducted on the opaqueexternal wall of an apartment house located in Seoul for two weeks in the winter and was performed in compliancewith the ISO 9869-1 standard. As a results of the measurement, U-value and R-value analyzed by PAM did not convergeduring the two weeks period, even though the experimental conditions specified in ISO 9869-1 were met. The analyticalresults by AMSE show that as the correction period to apply the storage effect becomes longer, the fluctuation of Uvalueand R-value greatly decrease and two values tend to converge to the respective asymptotical values. Therefore,although extensive research is needed for more cases, it is considered that AMSE can shorten the measurement periodto determine the U-value and R-value to a reasonable level of accuracy.
- 발행기관:
- 한국생활환경학회
- 분류:
- 학제간연구