애스크로AIPublic Preview
← 학술논문 검색
학술논문품질경영학회지2018.09 발행KCI 피인용 1

정부 품질보증활동 데이터 활용을 위한 Zero-Inflated 포아송 분포 적용

Application of Zero-Inflated Poisson Distribution to Utilize Government Quality Assurance Activity Data

김지훈(국방기술품질원); 이창우(국방기술품질원)

46권 3호, 509~522쪽

초록

Purpose: The purpose of this study was to propose more accurate mathematical model which can represent result of government quality assurance activity, especially corrective action and flaw. Methods: The collected data during government quality assurance activity was represented through histogram. To find out which distributions (Poisson distribution, Zero-Inflated Poisson distribution) could represent the histogram better, this study applied Pearson's correlation coefficient. Results: The result of this study is as follows; Histogram of corrective action during past 3 years and Zero-Inflated Poisson distribution had strong relationship that their correlation coefficients was over 0.94. Flaw data could not re-parameterize to Zero-Inflated Poisson distribution because its frequency of flaw occurrence was too small. However, histogram of flaw data during past 3 years and Poisson distribution showed strong relationship that their correlation coefficients was 0.99. Conclusion: Zero-Inflated Poisson distribution represented better than Poisson distribution to demonstrate corrective action histogram. However, in the case of flaw data histogram, Poisson distribution was more accurate than Zero-Inflated Poisson distribution.

Abstract

Purpose: The purpose of this study was to propose more accurate mathematical model which can represent result of government quality assurance activity, especially corrective action and flaw. Methods: The collected data during government quality assurance activity was represented through histogram. To find out which distributions (Poisson distribution, Zero-Inflated Poisson distribution) could represent the histogram better, this study applied Pearson's correlation coefficient. Results: The result of this study is as follows; Histogram of corrective action during past 3 years and Zero-Inflated Poisson distribution had strong relationship that their correlation coefficients was over 0.94. Flaw data could not re-parameterize to Zero-Inflated Poisson distribution because its frequency of flaw occurrence was too small. However, histogram of flaw data during past 3 years and Poisson distribution showed strong relationship that their correlation coefficients was 0.99. Conclusion: Zero-Inflated Poisson distribution represented better than Poisson distribution to demonstrate corrective action histogram. However, in the case of flaw data histogram, Poisson distribution was more accurate than Zero-Inflated Poisson distribution.

발행기관:
한국품질경영학회
DOI:
http://dx.doi.org/10.7469/JKSQM.2018.46.3.509
분류:
학제간연구

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
정부 품질보증활동 데이터 활용을 위한 Zero-Inflated 포아송 분포 적용 | 품질경영학회지 2018 | AskLaw | 애스크로 AI