ISO 9869-1의 평균법에 의한 겨울철 공동주택 외벽의 현장 열관류율 수렴성 분석

Convergence Analysis of In-situ Thermal Transmittance of Apartment House Opaque Exterior Wall in Winter Season by Average Method of ISO 9869-1

고명진(순천제일대학교); 이예지(인천대학교); 최두성(청운대학교)

25권 5호, 603~610쪽

초록

This study analyze the convergence of the in-situ thermal transmittance calculated by average method following ISO 9869-1 to the increase and change of measurement period. The measurement was conducted for an opaque exterior wall of an apartment house over a period of two weeks during winter. As a results of the measurement, the termination conditions were satisfied after eight days, more than twice the minimum required measurement period of three days, even though the experimental conditions recommended in ISO 9869-1 were met. The findings show that as the measurement duration(DT) increased, the termination condition that the thermal resistance obtained at the end of the test must not deviate by more than ±5% from the value obtained 24 h earlier, were easily achieved. On the other hand, other termination condition that the thermal resistance obtained by analyzing data from the first time period during INT(2×DT/3) days must not deviate more than ±5% from the value obtained from the data for the last period of the same duration are relatively difficult to achieve. This is because the environmental parameters of the first and last time periods must be similarly maintained within a stable range.

Abstract

This study analyze the convergence of the in-situ thermal transmittance calculated by average method following ISO 9869-1 to the increase and change of measurement period. The measurement was conducted for an opaque exterior wall of an apartment house over a period of two weeks during winter. As a results of the measurement, the termination conditions were satisfied after eight days, more than twice the minimum required measurement period of three days, even though the experimental conditions recommended in ISO 9869-1 were met. The findings show that as the measurement duration(DT) increased, the termination condition that the thermal resistance obtained at the end of the test must not deviate by more than ±5% from the value obtained 24 h earlier, were easily achieved. On the other hand, other termination condition that the thermal resistance obtained by analyzing data from the first time period during INT(2×DT/3) days must not deviate more than ±5% from the value obtained from the data for the last period of the same duration are relatively difficult to achieve. This is because the environmental parameters of the first and last time periods must be similarly maintained within a stable range.

발행기관:
한국생활환경학회
DOI:
http://dx.doi.org/10.21086/ksles.2018.10.25.5.603
분류:
학제간연구

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
ISO 9869-1의 평균법에 의한 겨울철 공동주택 외벽의 현장 열관류율 수렴성 분석 | 한국생활환경학회지 2018 | AskLaw | 애스크로 AI