애스크로AIPublic Preview
← 학술논문 검색
학술논문Nuclear Medicine and Molecular Imaging2019.06 발행KCI 피인용 4

Clinical Applications of Technetium-99m Quantitative Single-Photon Emission Computed Tomography/Computed Tomography

Clinical Applications of Technetium-99m Quantitative Single-Photon Emission Computed Tomography/Computed Tomography

이원우; K-SPECT Group

53권 3호, 172~181쪽

초록

Single-photon emission computed tomography/computed tomography (SPECT/CT) is an already established nuclear imaging modality. Co-registration of functional information (SPECT) with anatomical images (CT) paved the way to the wider application of SPECT. Recent advancements in quantitative SPECT/CT have made it possible to incorporate quantitative parameters, such as standardized uptake value (SUV) or %injected dose (%ID), in gamma camera imaging. This is indeed a paradigm shift in gamma camera imaging from qualitative to quantitative evaluation. In fact, such quantitative approaches of nuclear imaging have only been accomplished for positron emission tomography (PET) technology. Attenuation correction, scatter correction, and resolution recovery are the three main features that enabled quantitative SPECT/CT. Further technical improvements are being achieved for partial-volume correction, motion correction, and dead-time correction. The reported clinical applications for quantitative SPECT/CT are mainly related to Tc-99m-labeled radiopharmaceuticals: Tc-99m diphosphonate for bone/joint diseases, Tc-99m pertechnetate for thyroid function, and Tc-99m diethylenetriaminepentaacetic acid for measurement of glomerular filtration rate. Dosimetry before trans-arterial radio-embolization is also a promising application for Tc-99m macro-aggregated albumin. In this review, clinical applications of Tc-99m quantitative SPECT/CT will be discussed.

Abstract

Single-photon emission computed tomography/computed tomography (SPECT/CT) is an already established nuclear imaging modality. Co-registration of functional information (SPECT) with anatomical images (CT) paved the way to the wider application of SPECT. Recent advancements in quantitative SPECT/CT have made it possible to incorporate quantitative parameters, such as standardized uptake value (SUV) or %injected dose (%ID), in gamma camera imaging. This is indeed a paradigm shift in gamma camera imaging from qualitative to quantitative evaluation. In fact, such quantitative approaches of nuclear imaging have only been accomplished for positron emission tomography (PET) technology. Attenuation correction, scatter correction, and resolution recovery are the three main features that enabled quantitative SPECT/CT. Further technical improvements are being achieved for partial-volume correction, motion correction, and dead-time correction. The reported clinical applications for quantitative SPECT/CT are mainly related to Tc-99m-labeled radiopharmaceuticals: Tc-99m diphosphonate for bone/joint diseases, Tc-99m pertechnetate for thyroid function, and Tc-99m diethylenetriaminepentaacetic acid for measurement of glomerular filtration rate. Dosimetry before trans-arterial radio-embolization is also a promising application for Tc-99m macro-aggregated albumin. In this review, clinical applications of Tc-99m quantitative SPECT/CT will be discussed.

발행기관:
대한핵의학회
DOI:
http://dx.doi.org/10.1007/s13139-019-00588-9
분류:
핵의학

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
Clinical Applications of Technetium-99m Quantitative Single-Photon Emission Computed Tomography/Computed Tomography | Nuclear Medicine and Molecular Imaging 2019 | AskLaw | 애스크로 AI