동적법을 이용한 공동주택 외벽체의 현장 열저항과 열관류율 분석

Analysis of Thermal Resistance and Thermal Transmittance of Apartment House Opaque Exterior Wall by Application of Dynamic Method

문지훈(인천대학교); 이예지(인천대학교 대학원 도시건축학부); 고명진(대림대학교); 김용식(인천대학교)

27권 3호, 302~309쪽

초록

As the theoretically calculated thermal resistance and transmittance in the old buildings are reported to differ from values through measurement. it is essential to accurately diagnose thermal resistance and transmittance, and the average method suggested by ISO 9869-1 is used for accurate thermal diagnosis of the exterior wall. Average method requires more than 10oC of temperature difference between indoor and outdoor, and requires a long-term measurement. On the other hand, the dynamic method can be analyzed even if the temperature difference is small. And many research has shown that the measurement period can be shortened. In this study, in order to calculate the dynamic method by ISO 9869-1, in-situ measurements were conducted on the exterior wall of the apartment for 3 weeks. In addition, thermal resistance and transmittance were derived using R program. As a result of confirming the change in value as the measurement period increased, it converged to a certain point and the thermal resistance was 0.984±0.004m2· K/W, thermal transmittance was 0.912±0.004 W/m2·K. Compared to the final thermal resistance and transmittance by the average method, it is analyzed at the deviation of 0.4%. and it can be that the calculation of thermal resistance and transmittance by the dynamic method is reasonable.

Abstract

As the theoretically calculated thermal resistance and transmittance in the old buildings are reported to differ from values through measurement. it is essential to accurately diagnose thermal resistance and transmittance, and the average method suggested by ISO 9869-1 is used for accurate thermal diagnosis of the exterior wall. Average method requires more than 10oC of temperature difference between indoor and outdoor, and requires a long-term measurement. On the other hand, the dynamic method can be analyzed even if the temperature difference is small. And many research has shown that the measurement period can be shortened. In this study, in order to calculate the dynamic method by ISO 9869-1, in-situ measurements were conducted on the exterior wall of the apartment for 3 weeks. In addition, thermal resistance and transmittance were derived using R program. As a result of confirming the change in value as the measurement period increased, it converged to a certain point and the thermal resistance was 0.984±0.004m2· K/W, thermal transmittance was 0.912±0.004 W/m2·K. Compared to the final thermal resistance and transmittance by the average method, it is analyzed at the deviation of 0.4%. and it can be that the calculation of thermal resistance and transmittance by the dynamic method is reasonable.

발행기관:
한국생활환경학회
DOI:
http://dx.doi.org/10.21086/ksles.2020.06.27.3.302
분류:
학제간연구

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
동적법을 이용한 공동주택 외벽체의 현장 열저항과 열관류율 분석 | 한국생활환경학회지 2020 | AskLaw | 애스크로 AI