Utility of 99m Tc-Sulfur Colloid Lymphoscintigraphy and SPECT/CT in Chylothorax and Chylous Ascites

Utility of 99m Tc-Sulfur Colloid Lymphoscintigraphy and SPECT/CT in Chylothorax and Chylous Ascites

Jasim Jaleel(All India Institute of Medical Sciences); Syeddharvesh Nasurudeen(All India Institute of Medical Sciences); Anushna Sunila Babu(All India Institute of Medical Sciences); Priyanka Gupta(All India Institute of Medical Sciences); Bangkim Chandra Khangembam(All India Institute of Medical Sciences); Chetan Patel(All India Institute of Medical Sciences); Rakesh Kumar(All India Institute of Medical Sciences)

57권 6호, 265~274쪽

초록

Purpose To assess the diagnostic efficacy of 99mTc-sulfur colloid lymphoscintigraphy in chylothorax and chylous ascites,and the utility of single-photon emission computed tomography-computed tomography (SPECT/CT) in localizing the sitesof leaks. Methods Data from patients who underwent lymphoscintigraphy for clinical suspicion of chylothorax or chylous asciteswere retrospectively analyzed. Biochemical fluid analysis was taken as the reference standard. Pleural fluid triglyceridelevel > 110 mg/dL (with pleural fluid/serum ratio > 1) and a cholesterol level < 200 mg/dL (with pleural fluid/serum ratio < 1)were considered confirmatory for chylothorax. Ascitic fluid triglyceride level > 200 mg/dL with a low cholesterol level (ascitesfluid/serum ratio < 1) was considered confirmatory for chylous ascites. Results 26 patients (15 males, 57.7%) aged 9 months to 68 years were enrolled in the study. Based on the reference standard,17 had chylothorax or chylous ascites (9 with surgical history). Lymphoscintigraphy was positive in 16 (with 1 false positive)and negative in 10 (with 2 false negatives). The sensitivity, specificity, negative predictive value, positive predictive value, andaccuracy of lymphoscintigraphy were 88.2% (63.6–98.5%), 88.9% (51.8–99.7%), 80.0% (51.6–93.8%), 93.8% (70.1–99.0%),and 88.5% (69.9–97.6%), respectively. SPECT/CT could localize sites of leaks in 61.5% (8/13) with a localization rate of77.8% (7/9) and 25.0% (1/4) in patients with surgical and nonsurgical causes, respectively. Conclusion 99mTc-sulfur colloid lymphoscintigraphy is a highly efficacious noninvasive modality to diagnose chylothorax orchylous ascites with a high positive predictive value. SPECT/CT could localize the sites of leaks more frequently in patientswith surgical causes.

Abstract

Purpose To assess the diagnostic efficacy of 99mTc-sulfur colloid lymphoscintigraphy in chylothorax and chylous ascites,and the utility of single-photon emission computed tomography-computed tomography (SPECT/CT) in localizing the sitesof leaks. Methods Data from patients who underwent lymphoscintigraphy for clinical suspicion of chylothorax or chylous asciteswere retrospectively analyzed. Biochemical fluid analysis was taken as the reference standard. Pleural fluid triglyceridelevel > 110 mg/dL (with pleural fluid/serum ratio > 1) and a cholesterol level < 200 mg/dL (with pleural fluid/serum ratio < 1)were considered confirmatory for chylothorax. Ascitic fluid triglyceride level > 200 mg/dL with a low cholesterol level (ascitesfluid/serum ratio < 1) was considered confirmatory for chylous ascites. Results 26 patients (15 males, 57.7%) aged 9 months to 68 years were enrolled in the study. Based on the reference standard,17 had chylothorax or chylous ascites (9 with surgical history). Lymphoscintigraphy was positive in 16 (with 1 false positive)and negative in 10 (with 2 false negatives). The sensitivity, specificity, negative predictive value, positive predictive value, andaccuracy of lymphoscintigraphy were 88.2% (63.6–98.5%), 88.9% (51.8–99.7%), 80.0% (51.6–93.8%), 93.8% (70.1–99.0%),and 88.5% (69.9–97.6%), respectively. SPECT/CT could localize sites of leaks in 61.5% (8/13) with a localization rate of77.8% (7/9) and 25.0% (1/4) in patients with surgical and nonsurgical causes, respectively. Conclusion 99mTc-sulfur colloid lymphoscintigraphy is a highly efficacious noninvasive modality to diagnose chylothorax orchylous ascites with a high positive predictive value. SPECT/CT could localize the sites of leaks more frequently in patientswith surgical causes.

발행기관:
대한핵의학회
DOI:
http://dx.doi.org/10.1007/s13139-023-00813-6
분류:
핵의학

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
Utility of 99m Tc-Sulfur Colloid Lymphoscintigraphy and SPECT/CT in Chylothorax and Chylous Ascites | Nuclear Medicine and Molecular Imaging 2023 | AskLaw | 애스크로 AI