The objective of this study was to develop an analytical method for m-xylenediamine (m-XDA), an aldehyde scavenger, in various food simulants and food matrices. The analysis was performed using HPLC–UV (270 nm) with a Capcell pak MGII C18 column (4.6 × 250 mm, 5 μm). The method validation encompassed evaluations of specificity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantification (LOQ) across five food simulants and six food matrices. In the calibration curve range of 1–100 μg/mL, excellent linearity was observed with R2 ≥ 0.9992. The accuracy and precision were within the ranges of 86.4–98.6% and 0.7–2.9 relative standard deviation (RSD%), respectively. The LOD and LOQ were in the ranges of 0.26–0.56 μg/mL and 0.79–1.71 μg/mL, respectively. The significance lies in the development of analysis methods for each food matrix, not only for smart packaging simulant analysis. This research makes it well-suited for smart packaging safety management.

Abstract

The objective of this study was to develop an analytical method for m-xylenediamine (m-XDA), an aldehyde scavenger, in various food simulants and food matrices. The analysis was performed using HPLC–UV (270 nm) with a Capcell pak MGII C18 column (4.6 × 250 mm, 5 μm). The method validation encompassed evaluations of specificity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantification (LOQ) across five food simulants and six food matrices. In the calibration curve range of 1–100 μg/mL, excellent linearity was observed with R2 ≥ 0.9992. The accuracy and precision were within the ranges of 86.4–98.6% and 0.7–2.9 relative standard deviation (RSD%), respectively. The LOD and LOQ were in the ranges of 0.26–0.56 μg/mL and 0.79–1.71 μg/mL, respectively. The significance lies in the development of analysis methods for each food matrix, not only for smart packaging simulant analysis. This research makes it well-suited for smart packaging safety management.

발행기관:
한국식품과학회
DOI:
http://dx.doi.org/10.1007/s10068-024-01646-5
분류:
식품과학

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
Development of analysis method for m-xylenediamine as aldehyde scavenger using HPLC–PDA | Food Science and Biotechnology 2025 | AskLaw | 애스크로 AI