화재 시 회전문 사용 유무에 따른 출구 밀집도 변화분석

Analysis of Exit Density Change Based on Revolving Door Usage During Fire Emergency

김주성(우석대학교 일반대학원 소방방재학과); 공하성(우석대학교)

27권 1호, 57~65쪽

초록

Revolving doors can impede rapid evacuation during fire emergencies due to their structural characteristics, which pose a potential hazard. This study utilized the Pathfinder simulation software to analyze and compare the Required Safe Egress Time (RSET) and occupant density based on revolving door passage speed and utilization rates under different evacuation scenarios. When both revolving doors and swing doors were operational, or when revolving doors were closed and only swing doors were used, areas with an occupant density exceeding 3 persons per square meter were observed in the entrance area. However, when revolving doors were deactivated and the width of swing doors was expanded, a reduction in RSET was observed, and no areas with an occupant density exceeding 3 persons per square meter were identified. Therefore, buildings equipped with revolving doors should acknowledge the risks associated with their use. They must ensure sufficiently wide emergency exits or implement systems that allow revolving doors to open during emergencies to facilitate efficient evacuation. Furthermore, it is crucial to establish additional regulations governing the operation and safety standards of revolving doors during emergency scenarios.

Abstract

Revolving doors can impede rapid evacuation during fire emergencies due to their structural characteristics, which pose a potential hazard. This study utilized the Pathfinder simulation software to analyze and compare the Required Safe Egress Time (RSET) and occupant density based on revolving door passage speed and utilization rates under different evacuation scenarios. When both revolving doors and swing doors were operational, or when revolving doors were closed and only swing doors were used, areas with an occupant density exceeding 3 persons per square meter were observed in the entrance area. However, when revolving doors were deactivated and the width of swing doors was expanded, a reduction in RSET was observed, and no areas with an occupant density exceeding 3 persons per square meter were identified. Therefore, buildings equipped with revolving doors should acknowledge the risks associated with their use. They must ensure sufficiently wide emergency exits or implement systems that allow revolving doors to open during emergencies to facilitate efficient evacuation. Furthermore, it is crucial to establish additional regulations governing the operation and safety standards of revolving doors during emergency scenarios.

발행기관:
대한안전경영과학회
분류:
안전공학

AI 법률 상담

이 논문의 주제에 대해 더 알고 싶으신가요?

460만+ 법률 자료에서 관련 판례·법령·해석례를 찾아 답변합니다

AI 상담 시작
화재 시 회전문 사용 유무에 따른 출구 밀집도 변화분석 | 대한안전경영과학회지 2025 | AskLaw | 애스크로 AI