건축물 내부 연기농도변화에 따른 재실자의 영상출력 피난구유도등의 인지분석
A Cognitive Analysis of Image Output and Evacuation Zone Guided by Resident according to the Change in Smoke Concentration inside the Building
김상식(우석대학교 일반대학원 소방방재학과)
27권 1호, 75~80쪽
초록
This study was conducted through experiments by producing an image output evacuation guide light linked with a smoke detector. To summarize the results, first, the biggest recognition distance of the door at 30% smoke concentration was found to be the image output evacuation guide light. This is because of visual impairment and fear caused by indoor smoke, and in the process of finding the light of the emergency exit, accurate recognition of the evacuation behavior was searched even at the farthest distance, and it is judged that the time required for evacuation was short. Second, the biggest recognition distance of the door at 70% smoke concentration was the image output evacuation guide light, which showed the longest recognition distance. It is judged that even in smoke with many evacuees, the door is accurately recognized while seeing the light of the image output evacuation guide light and exits safely. Third, when the smoke concentration was 100%, the smoke rose and the evacuation guide light at the top of the door was not identified as thick smoke, and the image output evacuation guide light was displayed on the bottom of the passage, indicating that the evacuee accurately recognized the door and escaped safely to the outside even from a long distance.
Abstract
This study was conducted through experiments by producing an image output evacuation guide light linked with a smoke detector. To summarize the results, first, the biggest recognition distance of the door at 30% smoke concentration was found to be the image output evacuation guide light. This is because of visual impairment and fear caused by indoor smoke, and in the process of finding the light of the emergency exit, accurate recognition of the evacuation behavior was searched even at the farthest distance, and it is judged that the time required for evacuation was short. Second, the biggest recognition distance of the door at 70% smoke concentration was the image output evacuation guide light, which showed the longest recognition distance. It is judged that even in smoke with many evacuees, the door is accurately recognized while seeing the light of the image output evacuation guide light and exits safely. Third, when the smoke concentration was 100%, the smoke rose and the evacuation guide light at the top of the door was not identified as thick smoke, and the image output evacuation guide light was displayed on the bottom of the passage, indicating that the evacuee accurately recognized the door and escaped safely to the outside even from a long distance.
- 발행기관:
- 대한안전경영과학회
- 분류:
- 안전공학